Home Informatica PowerCenter administration Some issues of PowerCenter 9.0 to 9.0.1 upgrade

Some issues of PowerCenter 9.0 to 9.0.1 upgrade

Written by 
Rate this item
(1 Vote)

The article discusses some issues regarding an upgrade from PowerCenter 9.0 to 9.0.1. The rules seem to apply every PowerCenter version.

 

 

After upgrading Informatica PowerCenter, the INFA_HOME operating system environment variables must be set to a new PowerCenter installation path:

 

For example, when upgrading from 9.0 to 9.0.1, the path:

INFA_HOME=/opt/Informatica/9.0

is changed to path

INFA_HOME=/opt/Informatica/9.0.1

 

Other PowerCenter environment variables are relative to the INFA_HOME environment variable. Therefore, one need not apply any further changes, but it is worthwhile to check if the above statement is true.

 

An example setting for other PowerCenter environment variables is presented below:

 

INFA_HOME=/opt/Informatica/9.0.1

INFA_DOMAINS_FILE=$INFA_HOME/domains.infa

PM_ROOT=$INFA_HOME/server/infa_shared

PM_HOME=$PM_ROOT

PATH=$PATH:$INFA_HOME/server/bin

LD_LIBRARY_PATH=$LD_LIBRARY_PATH:$INFA_HOME:$INFA_HOME/server/bin

 

JRE_HOME=$INFA_HOME/Java

 

For each Integration Service make sure that $PMRootDir variable is set properly. Is should be set to path:

<INFA_HOME path>/server/infa_shared

Where <INFA_HOME path> is PowerCenter installation directory, defined by INFA_HOME environment variable.

 

 

Read 4348 times